Description
Hydrogen Generator for large ICE
Common Hydrogen Generator configuration for large engines – specification:
Hydrogen Generator for large ICE includes the following:
Electrolyzer HC12/24V Pro – 2pcs.
1.Operating voltage – 11-14.2 V
2.Load current from 10 to 60 A
3. Operating temperature – 15 to +50 degrees
4. Current consumption level meter
5. Electrolyte concentration – 10 – 14%
6. Brown’s Gas performance up to 2 l/m.
7.Overall dimensions (mm): H=220 , L=205 , W=175
8. Material
8.1.Box – stainless steel
8.2.Electrodes – 316L steel
Process Controller with PWM for NNO
1.Operating voltage 13/28 V
2.Operating frequency – 1-3 kHz
3.Output current – <60A
4.Operating temperature – -15 to 80 degrees
5.Adjustment method – two-level pulse width modulation
6.Frequency of control. speed control signal 10-350 Hz
7.Control e.g. – 0,8 – 4,5 V
8.Box material – polyester
9.Dimensions (mm) – L=199,4, H=43,2, W=84
Current consumption: 60A
Level meter – LM1
1.Supply voltage – 12-14V
2.Current consumption :< 10ma
Water filter – 2 pcs.
Performs the function of:
1.Steam fraction filter and electrolyte splash
2.Arrestor – blocks the path of the flame on recoil
3.Expansion vessel
4.Alkali fraction neutralizer
Electrolyte
KOH – sodium base – 2 kg
Cables
Red 20 sq. mm. – 6 m.
Black 20 sq. mm. – 1,5 m.
Red/black – 2×0,35 sq. mm. – 20 m.
Relay 24V – 30/40 A – 2 pcs.
Copper cable lug – 6×10 – 2 pcs.
Cable lug 6×5 – 2 pcs.
Bolt 4 mm – 2 pcs.
Nut 4 mm – 2 pcs.
Washer 4 mm – 2 pcs.
Master clamp 6 sq. mm. – 4 pcs.
0,5 sq. mm. – 2 pcs.
Plug for HHO gas supply – 1 pc.
Hose 8/11 mm – 20 m.
Hose clamps – 10 pcs.
Key for unscrewing the water filter jar – 1 pc.
Brown’s gas generator is IP54 rated for protection against water and moisture.
Hydrogen Generator operating conditions for large engines:
– altitudes up to 2000m;
– ambient temperature from -15°C to +50°C;
– maximum relative humidity 80% for temperatures up to 31°C, decreasing linearly to 40% relative humidity at 50°C;
– supply voltage deviation up to ±10% of the declared voltage;
– environment with pollution degree 3.
В Мултипроцесорния контролер има вградена защита от претоварване на алтернатора на автомобила, която следи напрежението в инсталацията на автомобила. При натоварване на системата изключва Водородната клетка до момента в който е на лице достатъчно напрежение за работата на всички системи в автомобила. Така се гарантира че Генератора на газ на Браун работи само с излишния ток произвеждан от алтернатора и не се ползва ток от акумулатора. (Тези тежки режими са характерни при работа на ниски обороти и празен ход на ДВГ.) Само нашия Мултипроцесорен контролер осигурява добър старт на двигателя като не натоварва акумулатора. Той включва клетката чак след стартиране на ДВГ и достигане до над 800 оборота и ако е започнало зареждане на акумулатора с напрежение над 13,2 волта. HHO генератора отговаря на БДС – изследван е в лаборатория и е проведена процедура по оценяване на съответствието съгласно Директива 2006/95/ЕС и е маркиран с европейски инициал за съответствие СЕ .