H2 inhalation reduces liver injury in swine hepatotectomyScientific Research


original title: Inhalation of hydrogen gas reduces liver injury during major hepatotectomy in swine

Authors:

Lei Xiang, Jing Tan, Li Huang, Lin Jia, Ya Liu, Yu Zhao, Kai Wang, Jia Dong

DOI: 10.3748/wjg.v18.i37.5197

-

Abstract:

To study the effect of H(2) gas on liver injury in massive hepatectomy using the Intermittent Pringle maneuver in swine. Male Bama pigs (n = 14) treated with ketamine hydrochloride and Sumianxin II as induction drugs followed by inhalation anesthesia with 2% isoflurane, underwent 70% hepatotectomy with loss of bleeding less than 50 mL, and with hepatic pedicle occlusion for 20 min, were divided into two groups: Hydrogen-group (n = 7), the pigs with inhalation of 2% hydrogen by the tracheal intubation during major hepatotectomy; Contrast-group (n = 7), underwent 70% hepatotectomy without inhalation of hydrogen. Hemodynamic changes and plasma concentrations of alanine aminotransferase (ALT), aspartate aminotransferase (AST), hyaluronic acid (HA), tumor necrosis factor-α (TNF-α), interleukin-6 (IL-6), and malondialdehyde (MDA) in liver tissue were measured at pre-operation, post-hepatotectomy (PH) 1 h and 3 h. The apoptosis and proliferating cell nuclear antigen (PCNA) expression in liver remnant were evaluated at PH 3 h. Then we compared the two groups by these marks to evaluate the effect of the hydrogen in the liver injury during major hepatotectomy with the Pringle Maneuver in the swine. There were no significant differences in body weight, blood loss and removal liver weight between the two groups. There was no significant difference in changes of portal vein pressure between two groups at pre-operation, PH 30 min, but in hydrogen gas treated-group it slightly decrease and lower than its in Contrast-group at PH 3 h, although there were no significant difference (P = 0.655). ALT and AST in Hydrogen-group was significantly lower comparing to Contrast-group (P = 0.036, P = 0.011, vs P = 0.032, P = 0.013) at PH 1 h and 3 h, although the two groups all increased. The MDA level increased between the two group at PH 1 h and 3 h. In the hydrogen gas treated-group, the MDA level was not significantly significant at pre-operation and significantly low at PH 1 h and 3 h comparing to Contrast-group (P = 0.0005, P = 0.0004). In Hydrogen-group, the HA level was also significantly low to Contrast-group (P = 0.0005, P = 0.0005) although the two groups all increased at PH 1 h and 3 h. The expression of cluster of differentiation molecule 31 molecules Hydrogen-group was low to Contrast-group. However, PCNA index (%) was not statistically significant between the two groups (P = 0.802). Microphotometric evaluation of apoptotic index (AI) in terminal deoxynucleotidyl transferase-mediated dUTP-biotin nick end labeling-stained tissue after hepatotectomy for 3h, the AI% level in the hydrogen was significantly low to Contrast-group (P = 0.012). There were no significant difference between Hydrogen-group and Contrast-group at pre-operation (P = 0.653, P = 0.423), but after massive hepatotectomy, the TNF-α and IL-6 levels increase, and its in Hydrogen-group was significantly low compared with Contrast-group (P = 0.022, P = 0.013, vs P = 0.016, P = 0.012), respectively. Hydrogen-gas inhalation reduce levels of these markers and relieved morphological liver injury and apoptosis. H(2) gas attenuates markedly ischemia and portal hyperperfusion injury in pigs with massive hepatotectomy, possibly by the reduction of inflammation and oxidative stress, maybe a potential agent for treatment in clinic.

Hydrogen Therapy At Home

Beyond clinical settings, hydrogen therapy is successfully used at home — thanks to our internationally recognised devices.

At “Hydrogen Technologies” Ltd., for more than 15 years we have been developing and manufacturing “HHO Bulgaria” devices for health with hydrogen.

We are among the pioneers in the field and, unlike many of our competitors worldwide, we continue to exist and to innovate!

By choosing “HHO Bulgaria”, you support both your own health and Bulgarian innovation and manufacturing.

Meet HBS10 — Europe’s best-selling hydrogen therapy device, both in Bulgaria and worldwide.

HBS10 — Hydrogen therapy device

HBS10 → More about HBS10 TOP PRODUCT

Inhalation and water

H2 therapy device
2-in-1

Output

Hydrogen inhalation
450 ml
HHO gas per minute

Concentration

Hydrogen water
-250 mV
ORP

The device is a 2-in-1 system: use it for hydrogen inhalation or to prepare hydrogen-rich water (“hydrogen water”).

HBS10 is the only European hydrogen therapy device chromatographically tested for safety at the Bulgarian Academy of Sciences (BAS)!

In addition, the device is:

  • CE certified;
  • Tested and recommended by the renowned hydrogen therapy platform H2HUBB, USA.

Order online

H2BOOSTR Mini is our newest alternative for hydrogen therapy at home.

H2BOOSTR Mini — hydrogen water system with 100% pure molecular hydrogen

H2BOOSTR Mini → More about H2BOOSTR NEW

100% pure molecular hydrogen

100%
pure molecular
hydrogen

Ready in 30 seconds

30 seconds
to prepare

High hydrogen concentration

3.2–3.6 mg
hydrogen
per litre of water

The system saturates water with 100% pure molecular hydrogen (“hydrogen water” with maximum dissolved hydrogen).

H2BOOSTR Mini reflects Bulgarian innovation: the technology is fully engineered in Bulgaria and is the world’s only solution that prepares one litre of hydrogen water in just 30 seconds with over 3 ppm of 100% pure molecular hydrogen!

Order online

FREE PERSONAL
CONSULTATION

  • SHORT AND
    STRAIGHT TO THE POINT
  • SPECIFIC
    TO YOUR NEEDS
  • CLEAR, AND IN
    EASY-TO-UNDERSTAND LANGUAGE

Discover How Molecular Hydrogen Therapy
can help You
and Your Loved Ones.

Ask The World's First Specialized H2 Consultant,
equipped with knowledge acquired from:

2500+

Clinical Studies,
Scientific Reports and Publications
conducted Worldwide

Analyses, consultations and summaries, prepared and published on our websites by Medical Specialists:

  • Dr. Ivan Vlasov
  • Dr. Victoria Kaludova
Sylvia Panayotova - H2 Consultant

Trained by:

Sylvia
Panayotova

Hydrogen Therapy Consultant,
certified by the Molecular Hydrogen
Institute (MHI) in the U.S.